time 01

NMIM Publications

An improved design of photovoltaic/thermal solar collector

An improved design of photovoltaic/thermal solar collector
Expired
/ Title

An improved design of photovoltaic/thermal solar collector

/ Authors

F. Hussain 1, M.Y.H. Othman 2, B. Yatim 2, H. Ruslan 2, K. Sopian 2, Z. Anuar 1, S. Khairuddin 1

  1.  National Metrology Institute of Malaysia, Lot PT 4803 Bandar Baru Salak Tinggi, 43900 Sepang, Malaysia
  2. Universiti Kebangsaan Malaysia, 43600 Bangi, Malaysia
Image
/ Journal

Solar Energy 122 (2015) 885–891, October 2015

/ Abstract

An improved photovoltaic/thermal (PV/T) solar collector combined with hexagonal honeycomb heat exchanger was studied. It is a combination of photovoltaic panel and solar thermal components in one integrated system. The honeycomb was installed horizontally into the channel located under the PV module. Air, as heat remover fluid is made to flow through the honeycomb.

The system was tested with and without the honeycomb at irradiance of 828W/m2 and mass flow rate spanning from 0.02kg/s to 0.13kg/s. It was observed that the aluminium honeycomb is capable of enhancing the thermal efficiency of the system efficiently. At mass flow rate of 0.11kg/s, the thermal efficiency of the system without honeycomb is 27% and with is 87%. The electrical efficiency of the PV module improved by 0.1% throughout the range of the mass flow rate. The improved design is suitable to be further investigated as solar drying system and space heating.

Image
National Metrology Institute of Malaysia (NMIM)
Lot PT 4803, Bandar Baru Salak Tinggi
43900 Sepang
Selangor Darul Ehsan

WhatsApp

+6018–2121 833

Corporate Inquiries

irene@sirim.my
+603 - 8778 1605 

Service Inquiries

serviceNMIM@sirim.my
+603 - 8778 1604

Complaint & Feedback

Training Course Request